OPTIMA EX
Air handling unit

OPTIMA EX

Sectional air handling unit for potentially explosive atmospheres

The OPTIMA EX air handling units are a series of devices designed for use in potentially explosive atmospheres. These units have been designed as an advanced mechanical ventilation solution for industrial facilities with an increased risk of explosion.

OPTIMA EX units comply with EU Directive 2014/34/EU and standards PN-EN ISO 80079-36:2016-07 and PN-EN 1127-1:2011, ensuring compliance with essential health and safety requirements. The units incorporate components designed for use in explosive atmospheres, including direct-drive fan assemblies for use with a frequency converter, flexible connections made of antistatic material, and specially designed multi-leaf dampers with a tightness class of 2 or 4 —in accordance with EN 1751—and filters designed in compliance with ATEX. As a result, the units are ideal for ventilating spaces where a potentially explosive atmosphere may be present, with the possibility of use in explosion hazard zones 1, 2, 21, and 22—depending on the selected technical solutions.

21 sizes; airflow from 500 to 80,000 m³/h.
CERTIFICATES
Graphic showing hygiene approval marks, TÜV Rheinland, CE, EcoDesign and SGS.
Download

KEY FEATURES

OPTIMA EX air handling unit with air intake and exhaust openings.

Protective roof over the casing of an outdoor air handling unit.

INSTALLATION
For outdoor installation, an additional weatherproof roof is used.

Structural profiles and joints in an air handling unit section.

CONSTRUCTION
Aluminum profile frame construction.

Casing panel layers with insulation between the outer sheets.

INSULATION
Insulation 50 or 63 mm thick in the form of panels filled with mineral wool

rama

FRAME
A 120 mm high frame made of galvanized sheet metal with enhanced corrosion resistance.

CONFIGURATION
Available configuration: sectional

AC fan assembly inside an air handling unit section.

FAN UNIT MOTORS
AC motors (alternating current) for use with inverters

AC fan assembly inside an air handling unit section.

FAN UNIT MOTORS
AC motors (alternating current) for use with inverters

Glycol heat recovery system showing heat exchangers, pipework and fittings.

HEAT RECOVERY
High-efficiency heat recovery systems in the form of counterflow heat exchangers or heat exchangers filled with a heat transfer fluid.

Heat exchanger inside an air handling unit section.

HEAT EXCHANGER 
Any configuration of water- or refrigerant-based Any configuration of water- or refrigerant-based heat exchangers operating in both heating and cooling modes. 

Measurement ports fitted to the air handling unit casing.

ACCESSORIES
Equipotential bonding to discharge electrical charges.

EQUIPMENT

  • run-around heat recovery system
  • counterflow heat exchanger
  • integrated heat pump
    AC fans
  • filters class F5–F9 (PM10 60% – PM1 80%)
  • water heating coil
  • cooling coil: water or DX
  • steam or adiabatic humidifier
  • run-around heat recovery installation (only in safe zone)
  • pump and control set for water heating coil (only in safe zone)
OPTIMA EX air handling unit with air intake and exhaust openings.

Our realizations

If you’re interested in this product, please contact us.
We will be happy to answer any questions.

Clima Gold: krótkie terminy realizacji. OPTIMA ELITE 10–15 od 4 tygodni; OPAL COMPACT 1–4 od 2 tygodni.